S11/S13/S20/S22 10kV oil-immersed distribution transformers (50-4000kVA) are widely used in 10kV distribution networks for direct power supply to end users. Typical applications include rural township...
View MoreProduct Overview Rated voltage 0.6/1kV cross-linked polyethylene insulated Grade B1 flame-retardant power cable (model: WDZB1-YJY) is a low-smoke halogen-free eco-friendly flame-retardant power cable. The insulation layer uses cross-linked polyethylene (XLPE) material, and the sheath uses low-smoke halogen-free high-resistance polyolefin material. The combustion performance grade reaches Grade B1 (Flame-retardant Level 1) as specified in GB 31247-2014 standard. During a fire, the cable can effectively prevent flame spread, does not release toxic halogen gases when burning, and significantly reduces smoke emissions, providing valuable time for personnel evacuation and fire rescue.
Model Designation and Description
|
Model |
Product Name |
|
WDZB1-YJY |
Copper core XLPE insulated LSZH sheathed Grade B1 flame-retardant power cable |
|
WDZB1-YJY23 |
Copper core XLPE insulated steel tape armored LSZH sheathed Grade B1 flame-retardant power cable |
|
WDZB1N-YJY |
Copper core XLPE insulated LSZH sheathed Grade B1 flame-retardant fire-resistant power cable |
|
WDZB1N-YJY23 |
Copper core XLPE insulated steel tape armored LSZH sheathed Grade B1 flame-retardant fire-resistant power cable |
Model code meanings: WD — Halogen-free low-smoke; ZB1 — Grade B1 flame-retardant; N — Fire-resistant; YJ — XLPE insulation; Y — Polyolefin sheath; 23 — Steel tape armoring.
Implementation Standards
|
Standard |
Scope |
|
GB 31247-2014 |
Combustion performance classification of cables and optical fiber cables — B1 grade determination basis |
|
GB/T 31248-2014 |
Test methods for flame spread, heat release, and smoke production characteristics of cables in fire |
|
GB/T 12706.1-2020 |
Cable structure, electrical and mechanical performance requirements |
|
GB/T 19666-2019 |
General rules for flame retardant and fire resistant cables |
|
XF/T 306-2025 |
Performance requirements and test methods for flame-retardant and fire-resistant cables |
Usage Characteristics and Technical Parameters
Electrical Performance:
- Rated Voltage (U0/U): 0.6/1kV; Frequency: 50Hz.
- AC Voltage Test: 3500V for 15 minutes without breakdown.
- Insulation Resistance Constant: >= 3.67 MOhm·km.
Working Temperature:
- Max long-term conductor temperature: 90°C.
- Max short-circuit temperature (<= 5s): 250°C.
- Laying temperature: >= 0°C (preheat if necessary).
Specification Range: 1.5 to 1000 mm²; 1, 2, 3, 4, 5 cores (including multi-core combinations).
Grade B1 Combustion Performance Details
Combustion Performance Classification: Per GB 31247-2014:
- Grade A: Non-combustible cables.
- Grade B1: Flame-retardant Level 1 (this product).
- Grade B2: Flame-retardant Level 2.
- Grade B3: Ordinary cables.
Important: Grade B1 is NOT the same as the ordinary flame-retardant Class B cable. Grade B1 evaluation involves over ten indicators including heat release, smoke characteristics, and smoke toxicity — far more stringent than the standard flame-retardant Grade B cable (which only assesses char height). Grade B1 cables must be halogen-free low-smoke eco-friendly cables.
Grade B1 Core Performance Indicators:
|
Test Item |
Requirement |
Meaning |
|
Flame Spread (FS) |
<= 1.5m |
Flame spread length <= 1.5m |
|
Peak Heat Release Rate |
<= 30kW |
Peak combustion heat release rate |
|
Total Heat Release (1200s) |
<= 15MJ |
Total heat over 1200 seconds |
|
Fire Growth Rate Index (FIGRA) |
<= 150W/s |
Lower = slower burning |
|
Peak Smoke Production Rate |
<= 0.25m²/s |
Smoke generation speed |
|
Total Smoke Production (1200s) |
<= 50m² |
Total smoke over 1200 seconds |
|
Smoke Density (Min. Transmittance) |
>= 60% |
Smoke concentration control |
Additional Classification Indicators:
- Flaming droplets/particles: d0, d1, d2. Grade B1 typically requires d0 (no flaming droplets in 1200s).
- Smoke toxicity: t0, t1, t2. Grade B1 typically requires t0 or t1.
- Corrosivity: a1, a2, a3.
Per DGJ08-2048-2016 and GB 50016-2018, super-high-rise buildings should select cables with combustion performance Grade B1 or above, toxicity t0, and droplet grade d0.
Product Structure
1. Conductor: Oxygen-free copper rod, resistivity below 0.01700 Ohm·mm²/m; approximately 8% more energy-efficient than standard copper rod.
2. Insulation: XLPE material using chemical cross-linking to convert linear PE into a 3D network structure with enhanced mechanical properties.
3. Filling and Oxygen Barrier Layer (armored type): Metal hydrates such as magnesium hydroxide release crystalline water during combustion, lowering cable flame temperature.
4. Armoring (YJY23 type): Double-layer galvanized steel tape gap winding; resists accidental mechanical force. The oxygen barrier design significantly improves flame-retardant and fire-resistant performance.
5. Sheath: Low-smoke halogen-free high-resistance polyolefin with excellent anti-corrosion properties.
VII. Main Application Scenarios
|
Application Area |
Typical Locations |
|
Urban construction |
High-rise, super-high-rise buildings, large commercial complexes |
|
Public transportation |
Metro, light rail, airports, stations |
|
Public facilities |
Hospitals, schools, convention centers, stadiums |
|
Critical facilities |
Data centers, financial centers, telecom hubs, power dispatch centers |
|
Special venues |
Hotels, theaters, shopping malls, nuclear power plants |
This product has been used in numerous major projects including Beijing Metro, Shenzhen Metro, Xi'an Metro, Shanghai Metro, and Suzhou Metro.
Selection and Acceptance Notes
1. Check Product Markings: Legitimate Grade B1 cables will clearly indicate "Grade B1 flame-retardant" on the product.
2. Request Certification Documents: Require supplier to provide combustion performance test reports and Combustion Performance Mark Authorization Certificate.
3. Verify Standards Compliance: Confirm compliance with GB 31247-2014 (combustion performance classification) and GB/T 12706.1-2020 (structural performance).
4. Additional Grade Selection: Select appropriate droplet grade (d0/d1), smoke toxicity (t0/t1), and corrosivity grade based on building type and usage requirements.
| Model | Voltage level | Specification (number of cores x cross-sectional area) | Execution standard | Manufacturing branch |
| WDZB1-YJY WDZB1N-YJY WDZB1-YJY63 WDZB1N-YJY63 |
0.6/1kV | 1×1.5~1×800 | Q/320481SS577-2024 | 50mm² and below special cable factory Low voltage cable factory with an area of over 50mm² |
| WDZB1-YJY WDZB1N-YJY WDZB1-YJY23 WDZB1N-YJY23 |
2×1.5~2×400 3×1.5~3×400 4×1.5~4×400 5×1.5~5×400 3×2.5+1×1.5~3×400+1×185 3×4+2×2.5~3×400+2×185 4×4+1×2.5~4×400+1×185 |
Special cable factory of 6mm² and below Low voltage cable factory with an area of 6mm² or more |
Hixon (Changzhou) Science and Technology Innovation Investment Co., Ltd. is located in Changzhou, Jiangsu, China. It is a comprehensive trading company specializing in the export of industrial products. With years of international trade experience, the company has established strong channel resources and project collaboration experience in the African market.