S11/S13/S20/S22 10kV oil-immersed distribution transformers (50-4000kVA) are widely used in 10kV distribution networks for direct power supply to end users. Typical applications include rural township...
View MoreProduct Overview This product is a copper-core PVC-insulated, PVC-sheathed, flame-retardant power cable for coal mines, suitable for AC 50Hz power supply and distribution lines in fixed installations underground or on the surface of coal mines, with a rated voltage U0/U of 0.6/1kV or below and 1.8/3kV. The product features excellent flame-retardant and safety performance, meeting the special environmental requirements of coal mines.
Implementation Standards
- GB/T 3956-2008: DC resistance of conductors.
- MT/T 386-2011: Flame-retardant performance.
- MT/T 818.12-2009: Coal mine cables — Part 12: PVC insulated power cables for coal mines rated 1.8/3kV and below.
Model and Specifications
|
Model |
Description |
Armoring |
Application |
|
MVV |
PVC-insulated, PVC sheathed coal mine power cable |
None |
Indoor, tunnels, pipes; no mechanical force |
|
MVV22 |
Steel tape armored coal mine power cable |
Double steel tape |
Underground, tunnels; withstands mechanical pressure but not large tensile force |
|
MVV32 |
Fine steel wire armored coal mine power cable |
Fine round steel wire |
Withstands significant mechanical tension |
|
MVV42 |
Thick steel wire armored coal mine power cable |
Thick round steel wire |
Withstands very large mechanical tension |
Specification Range (MVV and MVV22):
- 3-core at 0.6/1kV: 1.5 to 300 mm²; at 1.8/3kV: 10 to 300 mm².
- 3+1-core at 0.6/1kV: 4 to 300 mm²; at 1.8/3kV: 10 to 300 mm².
- 4-core at 0.6/1kV: 4 to 185 mm²; at 1.8/3kV: 4 to 185 mm².
Technical Parameters and Usage Conditions
Electrical Performance:
- Rated Voltage U0/U: 0.6/1kV or 1.8/3kV.
- AC voltage test (5min): 3.5kV (0.6/1kV) or 6.5kV (1.8/3kV) without breakdown.
- Conductor DC resistance (20°C): Complies with GB/T 3956-2008.
Thermal Performance:
- Max long-term allowable working temperature of conductor: 70°C.
- Max conductor temperature during short circuit (<= 5s): 160°C.
Installation Conditions:
- Installation temperature: Not lower than 0°C; preheat to above 0°C if needed.
- Minimum bending radius: >= 15 times the cable outer diameter.
- No laying drop restriction.
Flame-retardant Performance: Complies with MT/T 386-2011 standard for bundled flame retardancy.
Cable Structure
1. Conductor: Copper core (round or sector-shaped).
2. Insulation: PVC, with thickness varying by voltage rating.
3. Filling: Polypropylene mesh or hemp rope.
4. Inner sheath/wrapping: PVC or alkali-free glass fiber tape.
5. Armoring (MVV22/MVV32/MVV42): Double steel tape (2), fine round steel wire (3), thick round steel wire (4).
6. Outer Sheath: Flame-retardant PVC.
Product Features
- High Flame Retardancy: Special design and materials meeting MT/T 386 standards for safe operation in flammable/explosive environments.
- Chemical Resistance: Excellent resistance to acids, alkalis, and oils.
- High Drop Suitability: Suitable for vertical shaft installation and high-drop locations.
- Good Heat Resistance: Long-term operating temperature 70°C; short-term tolerance up to 160°C.
- Complete Safety Certification: Holds national mining product safety mark certification (MA) and CCC mandatory certification.
Purchasing and Application Notes
- Applications: Fixed installation underground in coal mines, central distribution rooms to mining substation, mobile substations.
- Compatible Voltages: 0.6/1kV for general coal mine power systems; 1.8/3kV for medium voltage fixed distribution equipment.
- Important: Due to the high dielectric loss of PVC insulation under strong electric fields, this product is not recommended for circuits above 3.6/6kV. Single-core cable armoring should use non-magnetic materials to prevent eddy current losses.
- Safety Certification: Products must have a valid MA safety certification before use in coal mines.
| Model | Voltage level | Specification (number of cores x cross-sectional area) | Execution standard | Manufacturing branch |
| MVV | 0.6/1kV | 3×(1.5~300)、4×(4~185)、 (3+1)×(4~300) |
MT/T 818-2009 | 6mm² and below control cable factory Low-voltage cable factory with an area of 6mm² or more |
| MVV22 | 3×(2.5~300)、4×(4~185)、 (3+1)×(4~300) |
|||
| MVV、MVV22 | 1.8/3kV | 3×(10~300)、4×(4~185)、 (3+1)×10~300 |
Hixon (Changzhou) Science and Technology Innovation Investment Co., Ltd. is located in Changzhou, Jiangsu, China. It is a comprehensive trading company specializing in the export of industrial products. With years of international trade experience, the company has established strong channel resources and project collaboration experience in the African market.
By integrating high-quality manufacturing resources with a well-established supply chain, we provide reliable product supply and professional trade services to global customers, aiming to become an important bridge connecting Chinese manufacturing to the global market.