S11/S13/S20/S22 10kV oil-immersed distribution transformers (50-4000kVA) are widely used in 10kV distribution networks for direct power supply to end users. Typical applications include rural township...
View MoreProduct Overview Rated voltage 0.6/1kV PVC insulated power cables (commonly known as plastic power cables) use Polyvinyl Chloride (PVC) as both insulation and sheath material. These cables are designed for power transmission and distribution in AC 50Hz systems with a rated voltage of 0.6/1kV and below. Standard models are used for general power lines. Flame-retardant (ZR) models are designed to inhibit fire spread, while fire-resistant (NH) models can maintain normal power supply for a specific period even when exposed to direct flames. These are essential for high-rise buildings, hospitals, subways, and other locations with high fire safety requirements.
Implementation Standards
The product is designed and manufactured according to the following standards:
- GB/T 12706.1-2020: Requirements for extruded insulated power cables up to 3kV.
- GB/T 19666-2019: General rules for flame-retardant and fire-resistant characteristics.
- GB/T 3956: Requirements for cable conductors (DC resistance).
- IEC 60502-1: International standard for power cables with extruded insulation.
- GB/T 18380 (IEC 60332): Tests on electric cables under fire conditions (Flame-retardancy).
- GB/T 19216 (IEC 60331): Tests for electric cables under fire conditions (Circuit integrity).
Common Models and Naming
- General Type: VV (Copper core), VLV (Aluminum core).
- Flame-retardant Type: ZR-VV, ZA-VV, ZB-VV, ZC-VV (Grades A, B, and C).
- Fire-resistant Type: NH-VV, NH-VV22.
- Armored Type: VV22 (Steel tape armored), VV32 (Fine steel wire armored).
Technical Parameters
1. Electrical Parameters:
- Rated Voltage (U0/U): 0.6/1kV.
- Highest System Voltage (Um): 1.2kV.
- AC Voltage Test: 3.5kV / 5min without breakdown.
- Insulation Resistance (20°C): >= 36.7 MOhm·km.
2. Temperature Ratings:
- Max long-term operating temperature: <= 70°C.
- Short-circuit temperature (<= 5s): 160°C (for section <= 300mm²) / 140°C (for section > 300mm²).
3. Minimum Bending Radius (D = Outer Diameter):
- Single-core: 20D (Unarmored) / 15D (Armored).
- Multi-core: 15D (Unarmored) / 12D (Armored).
Cable Structure
1. Conductor: Annealed copper or aluminum (Class 1 solid or Class 2 stranded).
2. Insulation: High-quality PVC compound.
3. Fire-resistant Layer (NH only): Multiple layers of mica tape wrapped over the conductor to maintain circuit integrity during fire.
4. Filling and Bedding: Non-hygroscopic materials to ensure a round cable shape.
5. Armoring: Double galvanized steel tape (22) or galvanized steel wire (32) for mechanical protection.
6. Outer Sheath: PVC or PE material.
Usage and Application
- VV / VLV: For indoor, tunnel, and pipe installations where mechanical force is not expected.
- VV22 / VLV22: For direct burial in the ground, capable of withstanding mechanical pressure.
- ZR-VV / ZA-VV: For public places with flame-retardant requirements.
- NH-VV: For fire emergency systems and high-safety environments.
Product Advantages
1. Cost-Effective: PVC provides high performance at a lower cost.
2. Easy Installation: Simple structure and lightweight design.
3. Chemical Resistance: Excellent resistance to oils, acids, and alkalis.
4. Safety: Reliable flame-retardant and fire-resistant performance ensures safety in emergencies.
| Model | Voltage level | Specification (number of cores x cross-sectional area) | Execution standard | Manufacturing branch |
| V(L)V V(L)Y VRV VRY |
0.6/1kV | 1×1.5~1×800、 (Among them, the five types of conductors have specifications ranging from 1 × 1.5 to 1 × 630) |
GB/T 12706.1-2020 Non-standard model execution Q/320481SS005-2024 |
50mm²and below control cable factory 50mm² The above low-voltage cable factory |
| 2×1.5~2×300、 3×1.5~3×300 4×2.5~4×400、 3×2.5+1×1.5~3×400+1×185 5×2.5~5*400、 3×2.5+2×1.5~3×400+2×185、 4×2.5+1×1.5~4×400+1×185 |
6mm²and below control cable factory 6mm² The above low-voltage cable factory |
|||
| Z*-V(L)V62 Z*-V(L)V72 |
1×4~1×800 | 50mm²and below control cable factory 50mm² The above low-voltage cable factory |
||
| Z*-V(L)V22 Z*-V(L)V32 Z*-V(L)V23 Z*-V(L)V33 |
2×1.5~2×300、3×1.5~3×300、 4×1.5~4×400、5×2.5~5×300、 3×2.5+1×1.5~3×400+1×185、 3×2.5+2×1.5~3×400+2×185、 4×2.5+1×1.5~4×400+1×185 |
6mm²and below control cable factory 6mm² The above low-voltage cable factory |
||
| Z*-V(L)V Z*-V(L)Y Z*-VRV Z*-VRY |
1×1.5~1×800 (Among them, the five types of conductors have specifications ranging from 1 × 1.5 to 1 × 630) |
50mm²and below control cable factory 50mm² The above low-voltage cable factory |
||
| 2×1.5~2×300 3×1.5~3×300 4×2.5~4×400 3×2.5+1×1.5~3×400+1×185 5×2.5~5*400、 3×2.5+2×1.5~3×400+2×185、 4×2.5+1×1.5~4×400+1×185 |
6mm²and below control cable factory 6mm² The above low-voltage cable factory |
|||
| MYJV、MYJV22 | 3×(10~300)、4×(4~185)、 (3+1)×(10~300) |
Hixon (Changzhou) Science and Technology Innovation Investment Co., Ltd. is located in Changzhou, Jiangsu, China. It is a comprehensive trading company specializing in the export of industrial products. With years of international trade experience, the company has established strong channel resources and project collaboration experience in the African market.
By integrating high-quality manufacturing resources with a well-established supply chain, we provide reliable product supply and professional trade services to global customers, aiming to become an important bridge connecting Chinese manufacturing to the global market.